INSPECCIÓN ELÉCTRICA:

  1. Resistencia de aislamiento:

    Más de 10 millones ohmios entre la carcasa y además con final del cable de plomo (color rojo) en 250 VDC

  2. Resistencia dieléctrica:

    No se encuentra daño en 500 V CC 60 seg o 600 V.A.C. 2 segundos, medida con corriente de disparo 5 mA entre la carcasa y el extremo del cable de plomo.

  3. Life expectancy:

    Expected average life for rated voltage and continuous operation is 50,000 hours(ambient temperature 25C and humidity 65%).

    Regarding definition of life expectancy : The fan motor is running continuously at normal temperature and normal humidity conditions at the rated voltage, initial characteristics are compared with the value after running, the levels are defined below:

    Item Level of Determination
    Current More than 15% of initial value
    R P M More than 15% of initial value
    Noise 5dB A in excess of initial value
    Starting Voltage More than 10% of initial value

    If any items above exceed the levels of determination failure will occure.

  4. Insulation Class:

    A Class

 

 